Hirayama HVP-50 Top Load Sterilizer with Dry cycle

Hirayama HVP-50 Top Load Sterilizer with Dry cycle without basket Top-Loading Autoclave with Fully Automatic Drying cycle using heat and vacuum
Manufacturer: Hirayama Sterilizers
SKU: AT-HVP-50 HVP-50
$22,950.00
$23,950.00

Hirayama HVP-50 Top Load Sterilizer with Dry cycle without basket. Top-Loading Autoclave with Fully Automatic Drying cycle using heat and vacuum

Space-saving design with lid opening upward.
Fully automatic drying cycle for solid loads uses heat and vacuum for faster and more efficient drying.
Lid safety interlock prevents lid opening when a cycle is in progress, the chamber is pressurized, or when the temperature exceeds 97°C.
Pre-vacuum cycle - vacuum pump removes air from the chamber when sterilizing solids such as glassware and pipette tips, thereby eliminating cold spots, and ensuring faster and more efficient sterilization.
One-touch lever to easily open and close chamber lid.
Liquid cycle for media and agar.
Process display shows the program progress selected and status of the sterilization cycle.
Cycle for wastes and glassware without drying.
Bacteria filter reduces re-contamination.
Door-closure sensor prevents a cycle from starting unless the door is closed properly.
HVP-50 size: 50 liters, 11.8" D, 28.0" H.

TEMPERATURE  
Operating Range
105ºC to 135ºC
Display Range
5ºC to 140ºC
GAUGE PRESSURE  
Operating Range (gauge)
3 to 28.4 psi (0.2 to 2.0 kg/cm² )
TIMER  
Sterilization
1 to 250 minutes
Drying
1 to 90 minutes
DIMENSIONS  
Overall (W x D x H)
20.1" x 24.8" x 40.9" (51 x 63 x 104) cm
Chamber
(Diameter x Height)
50 liter
11.8" x 28" (30 cm x 71 cm)
SAFETY DEVICES
Temperature- and pressure-sensitive lid interlock, over-pressure power cutoff, over-temperature power cutoff, low-water power cutoff, mechanical pressure relief valve, lid-closure detector, over-current detector and circuit breaker with ground fault circuit interrupter.
PROGRAMS  
1. For solids with drying
Heating and air removal from chamber by vacuum pump (pre-vac) -> Sterilization -> Water and steam exhaust (fast) -> Drying by heat and vacuum -> Completion
2. For wastes/solids without drying
Heating -> Pre-vac -> Sterilization -> Steam exhaust (fast) -> Completion
3. For liquids/agar
Heating -> Sterilization -> Auto steam exhaust (programmable rates, or ambient cooling w/o steam exhaust) -> Completion
4. Drying without sterilization
Drying with heat and vacuum (time programmable) -> Completion(for additional drying after Program #1, if desired)
ACCESSORIES  
Stainless steel
Mesh wire baskets, buckets (pails), and round test tube racks
Factory or field installed
Data logger
POWER  
Source
120V, 50/60 Hz, single phase (220V/240V available on request)
Consumption
2000 watts (2000 VA)
SHIPPING WEIGHT
291 lb (133 kg)
Products specifications
Sterilizer Type Automatic Sterilizer
Sterilizer Door Size 12 inches
Sterilizer Chamber Depth 28 inches
Sterilizer Dimension 20.1" x 24.8" x 40.9" (510mm x 630mm x 1040mm)
Sterilizer Chamber Volume 13 Gal/50 L
Vacuum Pump Yes
Sterilizer Power Voltage 120V Single Phase
Sterilzier Power Current 20A
Dry Mode Yes
Loading Methods Top Load (Vertical)
Sterilizer Program 1. For Solids W Drying, 2 For wastes/Solids WO Drying, 3. For Liquids/Agar, 4. Drying WO Sterilization
Sterilizer High Temperature 275F (134C)
Color Beige
Type of Heating Element Internal Heating Element
Type of Door Hinge Door
Laboratory Customer Yes
Industry Customer Yes
Government Customer Yes
Tattoo, Beauty Salon Customer No
Medical Doctor No
Dentist Customer No
FDA Certificate No
ASME Certificate No
CE Certificate Yes
ISO Certificate Yes
Printer Option
Warranty Parts and Labor 1 year