Hirayama HRH-110 Front Load Sterilizer with Drying

Hirayama HRH-110 Front Load Sterilizer with Drying
Manufacturer: Hirayama Sterilizers
SKU: HRH-110 AT-HRH-110
$43,500.00
$49,990.00

Hirayama HRH-110 Front Load Sterilizer with Drying, Front-Loading Autoclave with Fully Automatic Drying Cycle Using Heat and Vacuum

Front-loading design
Fully automatic operation from start to finish with or without drying.
One-touch door closing lever opens and closes the door easily, surely and safely.
Pre-vacuum cycle - vacuum pump removes air from the chamber when sterilizing solids such as glassware and pipette tips, thereby eliminating cold spots, and ensuring faster and more efficient sterilization.
Drying by heat and vacuum increases drying efficiency and reduces cycle times.
Additional drying mode for complete drying without having to run the sterilization cycle again.
Bacteria filter reduces re-contamination.
Lid safety interlock prevents lid from opening during a cycle, when the chamber is pressurized, or when the chamber temperature is above 97°C at which super-heated liquids might boil over when disturbed.
Door-closure sensor prevents a cycle from starting unless the door is properly closed.
HRH-110 size: 110 liters, 16.5" diameter, 31.3" depth.

MODEL
HRH-110
Outer Dimensions
(690W x 1150D x 1385H) mm, (27.2W x 45.3D x 54.5H) in
Chamber Size
(420 Diameter x 795 Height) mm, (16.5" Diameter x 31.3" Height) in
Chamber Material
Stainless steel SUS304
Sterilization Temperature
105ºC – 135ºC (programmable)
Temperature Display Range
5ºC - 137ºC
Sterilization Timer
1 ~ 60 min (remaining time displayed)
Drying Timer
1 ~ 120 min (remaining time displayed)
Sterilization and Operation Modes
  1. For solids - sterilization and drying
  2. For solids - sterilization without drying and fast exhaust
  3. For liquids - sterilization without drying and slow exhaust
  4. Supplementary drying (if needed after sterilization mode 1)
Maximum allowable Pressure (Gauge Pressure)
0.206MPa (2.06 bar)
Thermometer, Digital
5ºC - 137ºC
Pressure Gauge, Analog
-0.1 ~ 0.4 MPa (-1 to 4 bar)
Drying Method
Vacuum pump and heating
Safety Devices
  • Pressure Relief Valve
  • Breaker with GFIC
  • Vacuum Pump Breaker
  • Low-water Power Cut-off
  • Error Detection:
    Insufficient water in the exhaust bottle
    Wire breakage in temperature sensor
    Over heating, over cooling, and over pressure
    Door not properly locked
Standard Accessories
Drain hose, water supply hose, caster stopper, operation manual
Options
Data logger, floating (load) sensor, square type wire basket, wire basket with solid bottom and dressing case;
Power Source
AC220V / single phase
Power Consumption
3.2KW
Net Weight (approx.)
616 lb, (280 kg)
Products specifications
Sterilizer Type Automatic Sterilizer
Sterilizer Door Size 17 inches
Sterilizer Chamber Depth 30 inches
Sterilizer Dimension 27.2" x 45.3" x 54.5" (690mm x 1150mm x 1385mm)
Sterilizer Chamber Volume 29 Gal/110 L
Sterilizer Power Voltage 220V Single Phase
Sterilzier Power Current 15A
Dry Mode Yes
Loading Methods Front Load
Sterilizer Program 1. For Solids w Drying, 2. For Solid wo Drying, 3. For Liquid, 4. Extra Drying
Sterilizer High Temperature 275F (134C)
Color Beige
Type of Heating Element Internal Heating Element
Type of Door Hinge Door
Printer Option
Warranty Parts and Labor 1 year
Laboratory Customer Yes
Industry Customer Yes
Government Customer Yes
Tattoo, Beauty Salon Customer No
Medical Doctor No
Dentist Customer Yes
FDA Certificate No
ASME Certificate No
CE Certificate Yes
ISO Certificate Yes